Home       Products       Workshops       Modeling Tips       User Showcase       Support       Contact

 

ICPR Modeling Tips - Multiple Outlets and Boundary Conditions


 

It is possible to have multiple outlets in an ICPR model.  A node becomes an outlet when its type is set to a time-stage relationship.  These node types are considered boundary conditions for the model and a relationship of stage versus time must be provided for each outlet and for each storm event included in the simulation sequence.  For example, if you have two separate outlets for your model and you want to evaluate the 10-, 25- and 100-year 24-hour storm events, then a total of six time-stage tables are required.  Tables containing the time-stage data are assembled using the Boundary Stage feature of ICPR.  The following example illustrates how this is accomplished.

 

 

        

- 01 -                        - 02 -                        - 03 -                        - 04 -